Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Model:FT-SS4
Brand:fengtu
1. Chlorine Analyzers Product Introduction
SS4 model Chlorine Analyzers is an electrode method water quality analysis instrument that uses fully digital electrode detection to detect residual chlorine parameters in water quality.The instrument is equipped with the self-developed ftiot operating system, which is simple to operate, has stable performance, accurate measurement, and wide detection range.It has a built-in high-capacity rechargeable lithium battery, making it convenient for users to conduct water quality testing at any time in the field or laboratory.
2.Chlorine Analyzers host parameters
Charging input voltage | 4.5V-5.5V |
Charging current | <2A |
screen size | 3.5 inches |
screen resolution | 480*800☆ |
screen interface | MIPI DSI☆ |
USB interface | 2 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
Type-C | 1 (Supports external expansion of mouse, keyboard, 4G, etc.)☆ |
RS485 | 2 (Supports Modbus, json, asc input, etc.) |
External sensor supply voltage | 12V |
External sensor supply current | 1A |
operating system | ftiot (based on Linux-5.4)☆ |
CPU | 2*Cotex-A7, 650Mhz☆ |
RAM | 512M DDR3☆ |
Flash | 8G-64G |
OpenGL | ES 2.0☆ |
Wifi | support |
4G | Optional |
button | support |
capacitive touch screen | support |
software architecture | B/S☆ |
web access | Support☆ |
MTP mode | Support☆ |
Multiple terminal login | Support☆ |
IPV6 | Support☆ |
Sensor communication method | RS485, TCP, UDP, HTTP☆ |
Data forwarding method | RS485, TCP, UDP, HTTP☆ |
Remote SSH | Support☆ |
remote debugging | Support☆ |
3.Chlorine Analyzers sensor parameters and configuration
serial number | name | Measuring range | principle | Measurement accuracy | Configuration | Remark |
1 | temperature | 0~50℃ | High-precision digital sensor | ±0.3℃ | ||
2 | pH | 0~14(ph) | Electrochemistry (Salt Bridge) | ±0.1PH | ||
3 | ORP | -1500mv~1500mv | Electrochemistry (Salt Bridge) | ±6mv | ||
4 | Conductivity | 0~5000uS/cm,0~10000uS/cm | contact electrode method | ±1.5% | ||
5 | TDS | 0~20μS/cm (TDS 0-10mg/L) | contact electrode method | ±1.5% | ||
6 | salinity | 0-2.5ppt or 0-80ppt | contact electrode method | ±0.05ppt or ±1ppt | ||
7 | Sludge concentration | 0~20.000g/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
8 | Turbidity | 0~40NTU (low turbidity) | scattered light method | ±1% | Optional | |
0~1000NTU (medium turbidity) | scattered light method | ±1% | ||||
0~3000NTU (high turbidity) | scattered light method | ±1% | ||||
9 | Dissolved oxygen | 0~20mg/L | fluorescence lifetime method | ±2% | ||
10 | Ammonia nitrogen | 0~100mg/l | Ion selective electrode method | ±1mg | ||
11 | suspended solids | 0~2000mg/L | scattered light method | ±5% (depending on sludge homogeneity) | ||
12 | Residual chlorine | 0~5.00mg/L | Ion selective electrode method | ±5% of reading | ✔ | The accuracy is best when the flow rate is 0.42m/s-0.85m/s. |
13 | Chloride ions | 0-3500.0mg/L | Ion selective electrode method | ±5% | ||
14 | Total hardness | 0~1000.0mg/L | Ion selective electrode method | ±10% of reading | ||
15 | cod | 0~500mg/L | UV254 absorption method | ±5% | COD and chlorophyll are equipped with automatic cleaners to prevent biological adhesion and avoid light window pollution to ensure long-term monitoring is still stable; the automatic cleaning time and cleaning frequency can be set, and the power consumption is 0.7W | |
16 | Chlorophyll | 0~400ug/L | Fluorescence method | R2>0.999 |
The six elements in Weather Instruments usually refer to air temperature, humidity, air pressure, wind speed, wind direction, and rainfall amount. The air temperature reflects the degree of hotness or coldness of the air and has a significant impact on agricultural production, human comfort, etc. Hu...
The solar automatic weather station uses solar energy to generate electricity. Because it is equipped with a solar panel, it can operate in the field for a long time without being affected by the power supply. Moreover, it is fully automatic and realizes remote weather monitoring. Users only need to...
The integrated automatic rainfall monitoring station is an unattended rainfall monitoring equipment. It not only has the incomparable advantages of traditional rain gauges and manual observation instruments, but also plays a significant role in improving work efficiency and reducing human errors. Th...
The Negative oxygen ion monitoring station, as the core quantitative tool of a "natural oxygen bar", relies on technological means to transform the abstract air quality into perceivable and verifiable scientific indicators, playing an important supporting role in many fields such as ecolog...