Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

Model:FT-SFA
Brand:fengtu
1.Introduction to Buoy Water Monitoring
1.Buoy Water MonitoringSFA is an unattended data collection system that integrates data collection, storage, transmission and management. It is an automatic hydrological monitoring and reporting system for industrial and agricultural production, tourism, urban environmental monitoring, geological disasters, flood control, water supply scheduling, power station reservoir water management, etc. The powerful host computer software can remotely observe real-time water and rainfall information, and has database, report, download and other functions. Users can also use the well-functioning meteorological software to further process and analyze the recorded data.
2. The water quality monitoring system consists of six parts: water quality sensor, data acquisition instrument, communication system, power supply system, overall support, and water quality monitoring platform. It can simultaneously monitor water temperature, pH, dissolved oxygen, conductivity, ammonia nitrogen, turbidity, COD, and other water quality factors. The data acquisition instrument has data acquisition, real-time clock, data timing storage, parameter setting, and standard 2G/4G (GPRS) communication functions.
2. Buoy Water Monitoring Product Features
1. Easy to deploy: various types of probes are highly integrated and easy to install; free cloud platform services are provided, and the system can be quickly put online;
2. Easy maintenance: After the equipment is installed, it can work automatically without manual supervision. The normal operation of the equipment can also be ensured by remote monitoring;
3. Easy to expand: sensor probes all use a unified communication protocol, which can quickly connect to the original equipment and quickly expand monitoring parameters;
4. Low power consumption: The device can run for a long time in a low power consumption state, increasing the convenience of device use;
5. Real-time: The data monitored by the equipment is transmitted to the cloud platform in real time to improve the timeliness of environmental data feedback.
3. Buoy Water Monitoring Technical Parameters
1. Subject parameters
| product name | describe |
| Buoy Water Monitoring |
Real-time online monitoring of multiple parameters can be achieved. Battery charge monitoring can be realized. It can realize cloud platform data monitoring, data push, data storage and alarm functions; data wireless transmission function. The peak power consumption is 5W; the sensor power consumption is about 0.25W per sensor. Overall dimensions: 750mm*750mm*535mm. Float diameter 414mm Weight: 22kg |
| Collector data collection | Reliable operation, anti-interference, can integrate multiple RS485/MODBUS-RTU slave devices |
| Collector data output | 1 channel RS485/JSON protocol output |
| Battery | Lithium battery 12VDC, 20AH (default) |
| solar panel | 22.1V/50W (default) |
| Power supply capability | Customized selection; intermittent operation for more than 5 days on rainy days |
| Position indicator (optional) | Warning light;GPS positioning; |
| Monitoring Platform | Cloud platform; mobile phone/computer multi-terminal login |
| protecting mask | 304 stainless steel filter cartridge protective cover |
| Floating body | Diameter 414mm, spherical float * 4 engineering plastics |
2. Main parameters of optional sensors
| Model | Name | Measurement range | Principle | Measurement accuracy | Resolution | Is it standard equipment | Note |
| S1S | cod | 0~1000mg/L | UV254 absorption method | ±5%, ±0.3℃ | 0.1mg/L | cod turbidity integrated; brush self-cleaning, with temperature compensation | |
| Turbidity | 0~400NTU | Scattering light method | ±1%, ±0.3℃ | 0.1NTU | |||
| S2 | Water hardness | 0~1000.0mg/L | Contact method of electrode | Reading ±10%; ±0.3℃ | 0.1mg/L | ||
| S3 | pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH;±0.1℃ | 0.01 | With warm supplement | |
| pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH;±0.1℃ | 0.01 | |||
| S5 | Ammonium nitrogen | 0~1000mg/l | Ion selective electrode method | 10% of the reading, ±0.5℃ | 0.01mg | Ammonia nitrogen pH integrated; with temperature compensation | |
| pH | 0~14 (ph) | Electrochemistry (salt bridge) | ±0.1PH;±0.1℃ | 0.01 | |||
| S6 | ORP | -1500mv~1500mv | Electrochemistry (salt bridge) | ±6mv | 1mV | ||
| S7 | Electrical conductivity | 0~10000uS/cm | Contact method of electrode | ±1.5%; ±0.1°C | 1uS/cm | With warm supplement | |
| S7H | High range conductivity | 0~30000μS/cm | Contact method of electrode | ±1.5%; ±0.1°C | 1uS/cm | High range conductivity TDS salinity sensor; with temperature compensation | |
| TDS | 0-10000ppm | Contact method of electrode | ±1.5%; ±0.1°C | 1ppm | |||
| Salinity | 0-10000ppm | Contact method of electrode | ±1.5%; ±0.1°C | 1ppm | |||
| S8 | Dissolved oxygen | 0~20mg/L | Fluorescence lifetime method | ±2%, ±0.3℃ | 0.01mg/L | With warm supplement | |
| S9 | Turbidity | 0~1000NTU | Scattering light method | ±1%, ±0.3℃ | 0.1NTU | With warm supplement | |
| S10 | Suspended matter | 0~2000mg/L | Scattering light method | ±5% (depending on the homogeneity of the sludge) | 0.1mg/L | ||
| S11S | Sludge concentration | 0~20.000g/L | Scattering light method | ±5% (depending on the homogeneity of the sludge) | 0.001g/L | Brushed self-cleaning | |
| S15S | Chlorophyll | 0~400ug/L | Fluorescence method | R²>0.999 | 0.01ug/L | Self-cleaning with brush; with temperature compensation | |
| S16S | Cyanobacteria | 0~200.0Kcells/mL | Fluorescence method | R²>0.999 | 0.1Kcells/mL | Brushed self-cleaning | |
| S17S | Oil in water | 0~60ppm | Fluorescence method | 0.1ppm | 0.01ppm | Brushed self-cleaning | |
| S20 | Transparency | 50~1000mm | Scattering light method | ±5% (depending on the homogeneity of the sludge) | 1mm | With warm supplement | |
| S21 | Water temperature | −20℃~85℃ | High-precision digital sensor | ±0.1℃ | 0.1℃ |
We can customize appropriate testing solutions based on the actual situation of the customer and the technical indicators to be achieved.
Note: The sensor cannot be installed upside down or horizontally, but must be installed at an angle of at least 15 degrees.
The working environment of the above water quality sensors is 0-50℃, <0.3Mpa.
4. Buoy Water Monitoring Product Dimensions
5. Buoy Water Monitoring Equipment Installation Requirements
1. Stay away from high-power radio transmitters
2. Stay away from high-voltage transmission lines and microwave radio transmission channels
3. Try to be close to the data transmission network
4. Stay away from strong electromagnetic interference
Meteorological monitoring is closely intertwined with our daily lives. From daily commuting to agricultural production, from industrial operations to urban planning, meteorological information plays a pivotal role. Precise meteorological monitoring enables early warnings of severe weather events suc...
As a vital water transportation corridor, shipping safety in canals is of utmost importance. Visibility stands as one of the critical factors influencing canal navigation safety. During adverse weather conditions such as heavy fog or torrential rain that reduce visibility, ship operators face restri...
The Portable Weather Station with Screen (FT-PQX7) of the Seven-Element model can measure in real-time the wind speed (ranging from 0 to 70m/s), wind direction (0 to 360°), temperature (-40℃ to 80℃), humidity (0 - 100% RH), air pressure (300 - 1100hpa), illumination (0 - 157286LUX), and optical r...
Automatic meteorological observation system consists of sensors, a data collector, a power supply system, a support structure, and a cloud platform, capable of automatically and continuously collecting data such as temperature, humidity, pressure, wind, and precipitation. This system requires...